Assessing the quality of retrofits in solid wall dwellings

Glew, D; Smith, M B; Miles-Shenton, D and Gorse, C (2017) Assessing the quality of retrofits in solid wall dwellings. International Journal of Building Pathology and Adaptation, 35(5), pp. 501-518.

Abstract

Purpose The purpose of this paper is to provide a detailed appraisal of the quality of domestic retrofits. Design/methodology/approach This paper presents the results of technical surveys on 51 retrofits undertaken before, during and after the retrofits. Findings Failures are observed to be endemic and characterised into five themes: 72 per cent showed moisture issues pre-retrofit, 68 per cent had moisture risks post-retrofit, 62 per cent did not adopt a whole house approach, 16 per cent showed inadequate quality assurance protocols and 64 per cent showed evidence of insufficient design detailing. Each theme is further subcategorised with a view to identifying implications for future policy. Research limitations/implications The findings suggest the 10 per cent Ofgem retrofit failure rates predictions are an underestimate and so there may be a need for additional investigations to understand the trend across the UK. Practical implications Recommendations to reduce the failure rates may include making changes to the current inspection regime, widening understanding among installers; providing standard repeatable designs for repeated features; and empowering occupants to trigger inspections. Social implications The sample is representative of a substantial proportion of the homes in the UK suggesting that retrofit quality may in many instances be below the required standards. Originality/value Risks of moisture issues and underperformance in domestic retrofit are a concern for government industry and households. This research shows that many installation failures are the result of not implementing existing guidelines and a change to the enforcement of standards may be needed to enact a fundamental change in installer practice and process control.

Item Type: Article
Uncontrolled Keywords: survey; policy; unintended consequences; retrofit; domestic energy efficiency; moisture
Index terms: quality assurance, survey, moisture risk, unintended consequence, appraisal, methodology, process control, evidence, inspection, enforcement, household, installer, investigation, domestic energy efficiency
Subjects: energy systems, risk assessment, data collection methods, evaluation and assessment methods, control systems, practitioner, demography, quality assurance, environmental hazards, factor and component analysis, research methods, health safety and environment
Topics: Urban Studies, Quality Management, Risk Management, Roles and Professions, Sustainability, Health and Safety, Research Practice, Engineering Principles
Descriptive scope: 5 PCTEA

N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here