de Bem, D H; Lima, D P B and Medeiros-Junior, R A (2018) Effect of chemical admixtures on concrete's electrical resistivity. International Journal of Building Pathology and Adaptation, 36(2), pp. 174-187. ISSN 23984708
Abstract
Purpose: The purpose of this paper is to verify the influence of superplasticizer and air entrainment admixtures (AEs) in the electrical resistivity of concrete. Design/methodology/approach: Ten different types of concrete have been studied. Three levels of superplasticizer and air AEs have been used (0.20, 0.35 and 0.50 per cent). Concrete samples were cast and the electrical resistivity was monitored at the ages of 28, 63 and 91 days. Compressive strength and density tests have also been executed. Findings: The superplasticizer admixture presented an optimal level of 0.35 per cent that significantly increased the electrical resistivity. The air AEs at the same dosage caused a considerable decrease in the electrical resistivity. The concrete with air AEs showed highest resistivity/MPa ratio. Research limitations/implications: The results should be carefully extrapolated for other materials and admixtures. Practical implications: The usage of chemicals admixture in concrete is extremely common nowadays. However, only a few authors have studied the impact of such materials on the concrete’s electrical resistivity. Since many other researchers have already correlated electrical resistivity with other concrete’s properties, such as strength, setting time and corrosion probability, it is important to better understand how superplasticizers and air-entraining agents, for instance, impact the resistivity. Originality/value: The vast majority of studies only tested the resistivity of cement paste or mortar and usually for short period of time (up to 28 days), which seems not to be adequate since the cement reaction continues after that period. This paper fills this gap and studied the impact of admixture on concrete and for a period of 91 days.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | admixture; concrete; electrical resistivity; non-destructive testing |
| Index terms: | mortars (material), non-destructive testing, density, superplasticizer, admixture, methodology, corrosion, agent, dosage, compressive strength |
| Subjects: | material analysis and testing, research methods, professional development, building materials, health monitoring assessment and metrics, material degradation and durability, analytical methods, practitioner, materials science |
| Topics: | Roles and Professions, Construction Materials, Information Management, Engineering Principles, Research Practice, Health and Safety, Urban Studies |
| Descriptive scope: | 3 PCT |
N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here