Design limits for framed wall assemblies dependent on material choices for sheathing membranes and exterior insulation

Lee, I; Roppel, P; Lawton, M and Ferreira, P (2019) Design limits for framed wall assemblies dependent on material choices for sheathing membranes and exterior insulation. International Journal of Building Pathology and Adaptation, 37(4), pp. 426-447. ISSN 23984708

Abstract

Purpose: The purpose of this paper is to propose a methodology for evaluating the hygrothermal performance of framed wall assemblies based on design limits. This methodology allows designers to evaluate wall assemblies based on their absolute performance rather than relative performance which is typically done for most hygrothermal analysis. Design/methodology/approach: The approach in developing this methodology was to evaluate wall assemblies against three typical design loads (e.g. air leakage, construction moisture, rain penetration) and determine limits in minimum insulation ratio, maximum indoor humidity and maximum rain penetration rates. This analysis was performed at both the field area of the wall and at framing junctions such as window sills. Findings: The findings in this paper shows example design limits for various wall assemblies in heating-dominated climates in North America. Design limits for wall assemblies with moisture membranes of different vapour permeance are provided for both the field area of the wall and at window sills. Discussions about the importance of 2D hygrothermal simulation and performance of vapour permeable sub-sill membranes are also provided. Originality/value: This framework of hygrothermal analysis will enable designers to make better decisions when designing framed wall assemblies suitable to the local climate and interior specifications for their projects. It will also enable the development of a design tool that will allow designers to visually see the implications of certain design decisions and filter out designs that do not meet their design conditions.

Item Type: Article
Uncontrolled Keywords: design limits; hygrothermal
Index terms: designer, humidity, penetration, insulation, rain, hygrothermal performance, framing, specification, design decision, methodology, window
Subjects: profession, climate science, building materials, conceptual models, design practice, architectural elements, research methods, material properties and characteristics, contractual condition, market analysis
Topics: Sustainability, Roles and Professions, Construction Materials, Research Practice, Contract Administration, Design Practice
Descriptive scope: 3 PCT

N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here