Indoor environmental quality improvement of student dormitories in Tehran, Iran

Abdollahzadeh, N; Farahani, A V; Soleimani, K and Zomorodian, Z S (2023) Indoor environmental quality improvement of student dormitories in Tehran, Iran. International Journal of Building Pathology and Adaptation, 41(1), pp. 258-278. ISSN 23984708

Abstract

Purpose: University students spend a considerable amount of time in dorm rooms, where their environmental condition affects residents' health, well-being, sleep quality and the associated performance. Accordingly, this study aims to run an initial assessment of the environmental quality of two dormitory buildings in Tehran, using field studies and computational simulation, and then provide feasible optimized improvement strategies. The possible correlation between architectural elements and the environmental quality and the impact of proposed solutions on the annual energy use of these spaces are also discussed. Design/methodology/approach: Field studies and computational simulation. Findings: Results indicate that applied strategies, including shadings, reflectors, thermal and acoustic insulations, inlet vents and ceiling fans, can boost different aspects of the thermal condition, ventilation, acoustics and visual comfort by 21.77, 55.96, 20.69 and 50.37%, respectively. Accordingly, an acceptable comfort level can simply be achieved at a low cost by installing or replacing a few construction elements in dorm rooms. Nevertheless, a systematic architectural design can offer healthy spaces. For instance, south-facing rooms with large windows provide a higher level of thermal comfort and daylight quality. Research limitations/implications: This study shows that an acceptable level of IEQ can be achieved in dorm rooms by applying simple retrofit strategies. Moreover, energy consumption of dormitories can be significantly reduced using these solutions. However, the efficiency of the strategies in comparison to their economic aspects should be discussed, and results need to be further validated in real conditions. It is also recommended that a more extensive range of dormitory room typologies be studied in future studies. The results of this study are limited to the study context and so they can only be applied in case studies with similar use and climatic condition. Originality/value: While many studies have explored the environmental quality of dormitories in different climatic conditions, no significant work has been found in Iran, Tehran investigating feasible optimized improvement strategies responding to all IEQ aspects of acoustics, thermal comfort, air and visual quality. Accordingly, this study makes an initial assessment of IEQ factors in a typical dormitory complex, and then develops practical retrofit strategies to bring the environmental condition of these spaces close to the suggested standards.

Item Type: Article
Uncontrolled Keywords: architectural elements; computational simulation; indoor environmental quality; retrofit strategies; student dormitories
Index terms: visual comfort, energy use, future study, insulation, energy consumption, comfort, indoor environmental quality, thermal comfort, environmental quality, low cost, Tehran, ceiling fan, efficiency, case study, climatic condition, shading, retrofit strategy, university student, architectural design, window, methodology, well-being, sleep quality, dormitory, strategy, ventilation, field study
Subjects: research methods, performance management, design practice, architectural elements, management, sustainability assessment, renovation and retrofit, building design, Geography, health conditions and diseases, occupational health and safety management, environmental health, environmental engineering, air quality, mental health and wellbeing, research design and methodology, mechanical systems, data collection methods, construction type, climate science, building materials, curriculum design, bidding, energy systems
Topics: Quality Management, Design Practice, Education, Engineering Principles, Research Practice, Geographical Context, Health and Safety, Business Strategy, Sustainability, Construction Technology, Procurement
Descriptive scope: 5 PCTEA

N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here