Hulio, Z H and Jiang, W (2020) An assessment of effects of non-stationary operational conditions on wind turbine under different wind scenario. Journal of Engineering, Design and Technology, 18(1), pp. 102-121. ISSN 1726-0531
Abstract
Purpose: The non-stationary operational wind loads vary in time and site and has remarkable effect on wind turbine drive train. The purpose of this paper is to determine the effects of wind class 3 and 7 on the life of wind turbine drive train. The two-wind class 3 and 7 are described by average wind speed and weight factor and effects of two variables on wind energy generation and wind turbine drive train studied. Design/methodology/approach: The load distribution method is used to calculate stress range cycles for wind class 3 and 7. To determine the rise of force on wind turbine drive train, the load cycle method is proposed. The fatigue damage model is studied with respect to influence of different wind speeds and wind shear factor and then results analysed accordingly. Also sensitivity analysis has been carried out to assess the percentage of drop of energy generation and rise of tangential force for wind class 3 and 7. Linear fit method is used to determine the inclination of wind variation and wind shear of wind class 3 and 7. In this regard, two practical wind sites fall under the wind class 3 and 7 and 1.5 MW wind turbine have been taken in to account. Findings: The results showed that the average rise of force on wind turbine drive train is 37.5% which can influence the drop in energy 34.7% for wind class 3. Similarly, the results of wind class 7 are showing that the average rise in force and drop in energy found to be 49.05% and 51.16%, respectively. The wind class 7 have higher tendency of wind fluctuations and weight factor that can cause a damage to wind turbine drive train components. The results showed that when wind speed increases to rated power 11.5 m/s the damages occurred and remain steady. Similarly, when weight factor increased from 0.18 to onwards the damage occurred. The increased wind loads increased the tangential loads on the wind turbine decreased life of the gearbox. Originality/value: The results of study suggest that wind turbine should be design according to site specific wind environment for maximum energy generation and lowers the wind loads on the drive train component.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | component systems performance; drive train; electrical machines and energy generation from renewable resources; load distribution method; non stationary; operational conditions; tangential force; wind loads |
| Index terms: | methodology, variation, wind load, wind speed, renewable resources, sensitivity analysis, damages, fatigue, wind energy generation |
| Subjects: | environmental science, renewable energy, environmental resource management, dispute resolution, environmental hazards, health conditions and diseases, contractual condition, research methods, structural engineering |
| Topics: | Legal Issues, Contract Administration, Health and Safety, Research Practice, Engineering Principles, Sustainability |
| Descriptive scope: | 3 PCT |
N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here