Evaluation of the potential of water vapor to be used as a tracer gas for determining air change rates

Hakkarainen, M.; Oskierko-Jeznacki, E. and Braham, W. W. (2026) Evaluation of the potential of water vapor to be used as a tracer gas for determining air change rates. International Journal of Building Pathology and Adaptation, 44(9), pp. 1-15. ISSN 2398-4708

Abstract

Purpose – Conventional tracer gas testing, using conservative tracer gases (like SF6 or CO2), is the most accurate method for assessing air change rates, but it can be expensive and cumbersome to perform. Using water vapor as unconventional tracer gas has been proposed as an alternative, but it has not been broadly validated through the build environment. This paper evaluates water vapor tracer gas testing in a new context. Design/methodology/approach – Eight simultaneous water vapor and CO2 tracer gas tests were conducted on a Mongolian ger (or "yurt" in Russian). The air change rates from the water vapor (ACHH2O) and CO2 tracer gas tests (ACHCO2) were compared to evaluate the accuracy of the method. Findings – Under ideal conditions, the ACHH2O values were accurate within 21–41% of the ACHCO2 values (consistent with the literature). Indoor combustion and rainstorms were identified to cause higher errors (70–88% and 76%, respectively). Research limitations/implications – Limitations in the accuracy and deployment of the sensors made characterization of the air change rate (ACH) errors challenging. However, the agreement between the ACHH2O and ACHCO2 observed in this study was consistent with other lower cost alternatives to conventional tracer gas testing. Originality/value – This paper evaluates water vapor tracer gas testing in a new residential building type, and it is the first study to consider water vapor tracer gas testing in the presence of indoor combustion and after a rainstorm.

Item Type: Article
Uncontrolled Keywords: air change rate; air infiltration; Mongolian ger or yurt; tracer gas; water vapor
Index terms: infiltration, residential building, presence, testing, accuracy, methodology
Subjects: research methods, environmental science, professional practice, construction type, professional development
Topics: Construction Technology, Information Management, Research Practice, Sustainability, Engineering Principles
Descriptive scope: 3 PCT

N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here