Zhairy, A. E.; Daoud, A. O. and Mohamed, A. G. (2026) Transforming facility management with BIM, IoT, and digital twin: A data-driven approach to air quality monitoring. Architectural Engineering and Design Management, 22(2), pp. 426-445. ISSN 1745-2007
Abstract
Poor indoor air quality in healthcare facilities can significantly impact patient recovery, increase the risk of airborne disease transmission, and compromise staff well-being. Conventional monitoring methods typically rely on manual or static measurements, lacking the real-time responsiveness required for proactive facility management. This study proposes an integrated Building Information Modeling (BIM), Internet of Things (IoT), and Digital Twin (DT) framework to enable continuous air quality monitoring and data-driven decision-making. A case study was conducted in an Egyptian healthcare facility, where IoT sensors captured critical parameters, including airflow (CFM), pressure (Pa), CO₂ levels (ppm), and temperature (°C). These data were transmitted to ThingSpeak, a cloud-based analytics platform, and dynamically integrated into a BIM model using Dynamo scripts in Autodesk Revit. This integration enabled real-time, color-coded visualization of environmental conditions, supporting rapid, data-driven responses to changing air quality. A pilot study with a BIM expert validated the framework, highlighting challenges such as internet dependency, data security risks, interoperability limitations, and the limited availability of as-is BIM models. Despite these constraints, the system demonstrated its effectiveness in real-time monitoring and proactive facility management, providing a scalable, data-driven approach for improving operational efficiency and indoor air quality in healthcare environments.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | air quality monitoring; building information modeling; data integration; digital twin; facility management; healthcare facilities; internet of things; real-time monitoring |
| Index terms: | integration, platform, interoperability, building information modelling, efficiency, internet, recovery, script, visualization, effectiveness, well-being, data-driven decision-making, digital twin, air quality, disease transmission, monitoring, indoor air quality, case study, environmental conditions |
| Subjects: | performance management, decision analysis, data collection methods, sociology, organizational analysis, systems and processes, digital design, control systems, design practice, digital engineering, operations management, health risk and incident analysis, mental health and wellbeing, environmental health, computing systems, climate science, information systems, environmental science |
| Topics: | Research Practice, Digital Applications, Project Management, Quality Management, Site Management, Risk Management, Organizational Design, Health and Safety, Design Practice, Sustainability |
| Descriptive scope: | 3 PCE |
N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here