Harrington, S and Mulville, M (2023) The suitability of sensor-based demand controlled ventilation systems in retrofit dwellings: A longitudinal study. In: Tutesigensi, A and Neilson, C J (eds.) Proceedings of 39th Annual ARCOM Conference, 4-6 September 2023, University of Leeds, Leeds, UK.
Abstract
A fabric-first approach to dwelling retrofit results in increased airtightness, therefore there is an obligation to ensure that the upgrades do not lead to poor indoor air quality (IAQ) resulting from inadequate ventilation. The sensor-based demand-controlled ventilation (SBDCV) under review seeks to provide fresh air for breathing and to dilute and exhaust pollutants and odours. This system modulates the ventilation rate over time based on relative humidity levels and/or presence detection and considers that the level of ventilation provided is sufficient to control the concentration of all other indoor air pollutants, including those that are not a result of human occupancy. This research takes the form of a longitudinal study that follows a structured approach to monitor the levels of relative humidity, radon, and volatile organic compounds within participating dwellings (n=7) so that the relationship between the variables can be explored. This paper demonstrates that SBDCV systems are insufficient to ensure the removal of non-occupancy related pollutants. This could have significant health and wellbeing impacts for occupants. The findings of the paper have implications for the policy framework.
| Item Type: | Conference Paper (Paper) |
|---|---|
| Uncontrolled Keywords: | dwelling retrofit; demand controlled ventilation; relative humidity; radon; volatile organic compounds. |
| Index terms: | radon, indoor air quality, presence, odour, pollutant, suitability, relative humidity, health and wellbeing, ventilation |
| Subjects: | environmental hazards, environmental health, design criteria, mental health and wellbeing, air quality, environmental science |
| Topics: | Sustainability, Engineering Principles, Health and Safety, Design Practice |
| Descriptive scope: | 2 PC |
N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here