Ventilation strategies for urban housing: Lessons from a PoE case study

Macintosh, A and Steemers, K (2005) Ventilation strategies for urban housing: Lessons from a PoE case study. Building Research & Information, 33(1), pp. 17-31. ISSN 0961-3218

Abstract

Mechanical ventilation with heat recovery is still not widely used in UK housing, but with insulation and air-tightness standards becoming increasingly strict, it is likely to become more common. Operable windows are almost a given for housing and the UK climate is rarely extreme enough to restrict people's use of those windows for natural ventilation. This is a potential problem for the use of heat-recovery systems and could greatly reduce their energy efficiency. The paper takes the Iroko housing scheme at Coin Street, London, as a post-occupancy evaluation (PoE) case study to investigate the questions raised with respect to how well the occupants of the houses cope with balancing both natural ventilation and mechanical systems to achieve thermal comfort energy efficiently. First, the optimum balance of mechanical and natural ventilation is estimated and used to determine the maximum potential saving it could give when compared with natural ventilation alone. Short-term monitoring of the building in question together with the results of questionnaires showed why this theoretical balance is not achieved and that the energy consumption is likely to be worse than for natural ventilation alone. Noise, perceived control, perceived freshness and misunderstanding are all discussed as possible causes for the apparent disjunction. Misunderstanding on the part of residents was shown to be a critical determinant, so information about the heat recovery system was distributed to the residents and the paper ends by looking at what theoretical energy savings might be made as a result of this act.

Item Type: Article
Uncontrolled Keywords: Coin Street, London; heat recovery; Iroko housing; occupant behaviour; occupant control; urban housing; ventilation
Index terms: London, energy-saving, window, monitoring, energy consumption, thermal comfort, natural ventilation, questionnaire, determinant, perceived control, occupant behaviour, insulation, mechanical system, housing, recovery, heat recovery system, energy efficiency, case study, becoming, post-occupancy evaluation, strategy, mechanical ventilation, ventilation
Subjects: behavioral psychology, environmental engineering, philosophical process, management, architectural elements, Geography, operations management, building materials, sustainability and energy, evaluation methods, energy systems, air quality, mechanical systems, data collection methods, construction type, risk assessment, health behaviours and lifestyles, control systems
Topics: Business Strategy, Engineering Principles, Research Practice, Geographical Context, Project Management, Risk Management, Sustainability, Construction Technology, Design Practice, Quality Management, Site Management
Descriptive scope: 4 PCEA

N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here