Birchmore, R; Davies, K; Etherington, P; Tait, R and Pivac, A (2017) Overheating in Auckland homes: Testing and interventions in full-scale and simulated houses. Building Research & Information, 45(1-2), pp. 157-175. ISSN 0961-3218
Abstract
New Zealand dwellings have thermal conditions managed with relatively light regulation. No minimum airtightness standards exist and historical increases in required insulation levels aimed to reduce winter heating energy consumption. A consequence of this policy is an increased potential for overheating in summer. There has been a steady increase in the use of heat pumps, risking heating energy savings being outweighed by cooling energy increases. Internal temperatures and humidity were monitored in the living spaces of three unoccupied, transportable houses over all four seasons of the Auckland climate. The houses are located on the same site and are of identical construction, apart from selected interventions which were tested to explore their potential to mitigate overheating. Results indicate that overheating can be extreme and long lasting. High internal temperatures are very closely connected with solar gains. Internal temperatures reached 32°C in autumn. Roof space temperatures reached 51°C in summertime. Interventions resulted in modest improvements and an airtight construction provided a small thermal benefit. A thermal model for the houses was developed using EnergyPlus and compared with actual measurements and the interventions. Early results point to the further need to reduce solar gain, increase roof-space ventilation and increase mass, where feasible.; New Zealand dwellings have thermal conditions managed with relatively light regulation. No minimum airtightness standards exist and historical increases in required insulation levels aimed to reduce winter heating energy consumption. A consequence of this policy is an increased potential for overheating in summer. There has been a steady increase in the use of heat pumps, risking heating energy savings being outweighed by cooling energy increases. Internal temperatures and humidity were monitored in the living spaces of three unoccupied, transportable houses over all four seasons of the Auckland climate. The houses are located on the same site and are of identical construction, apart from selected interventions which were tested to explore their potential to mitigate overheating. Results indicate that overheating can be extreme and long lasting. High internal temperatures are very closely connected with solar gains. Internal temperatures reached 32°C in autumn. Roof space temperatures reached 51°C in summertime. Interventions resulted in modest improvements and an airtight construction provided a small thermal benefit. A thermal model for the houses was developed using EnergyPlus and compared with actual measurements and the interventions. Early results point to the further need to reduce solar gain, increase roof-space ventilation and increase mass, where feasible.;New Zealand dwellings have thermal conditions managed with relatively light regulation. No minimum airtightness standards exist and historical increases in required insulation levels aimed to reduce winter heating energy consumption. A consequence of this policy is an increased potential for overheating in summer. There has been a steady increase in the use of heat pumps, risking heating energy savings being outweighed by cooling energy increases. Internal temperatures and humidity were monitored in the living spaces of three unoccupied, transportable houses over all four seasons of the Auckland climate. The houses are located on the same site and are of identical construction, apart from selected interventions which were tested to explore their potential to mitigate overheating. Results indicate that overheating can be extreme and long lasting. High internal temperatures are very closely connected with solar gains. Internal temperatures reached 32 degrees C in autumn. Roof space temperatures reached 51 degrees C in summertime. Interventions resulted in modest improvements and an airtight construction provided a small thermal benefit. A thermal model for the houses was developed using EnergyPlus and compared with actual measurements and the interventions. Early results point to the fu ther need to reduce solar gain, increase roof-space ventilation and increase mass, where feasible.;
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | New Zealand; thermal performance; prefabrication; building performance; overheating; simulation; houses; energy; performance; risk; impact; construction & building technology; buildings; heat |
| Index terms: | winter, New Zealand, building technology, building performance, overheating, energyplus, ventilation, energy-saving, energy consumption, regulation, heat pump, summer, thermal performance, humidity, prefabrication, testing, roof, insulation |
| Subjects: | air quality, climate science, engineering systems, building materials, professional practice, energy systems, environmental science, design practice, Geography, building construction, quality assurance, political science, thermal systems |
| Topics: | Engineering Principles, Geographical Context, Governance, Sustainability, Construction Technology, Quality Management, Design Practice |
| Descriptive scope: | 3 PCA |
N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here