McGill, G; Sharpe, T; Robertson, L; Gupta, R and Mawditt, I (2017) Meta-analysis of indoor temperatures in new-build housing. Building Research & Information, 45(1-2), pp. 19-39. ISSN 0961-3218
Abstract
Despite growing concerns about overheating, a lack of evidence exists on the scale of the problem, particularly in contemporary UK housing. This paper presents the results of a meta-analysis of indoor temperatures in selected low-energy housing. Temperature data recorded at five-minute intervals in 60 dwellings across 19 demonstration projects (2012-14) were collated and analysed to investigate the prevalence of overheating. Findings evidence high summertime temperatures, with 27% of living rooms exceeding 28°C during August. Based on the Chartered Institution of Building Services Engineers (CIBSE) threshold of 5% annual occupied hours > 25°C, 57% of bedrooms and 75% of living rooms were classified as having overheated. Overall, 30% of living rooms exceeded the adaptive comfort threshold of > 3% occupied hours ΔT ≥ 1 K. The results suggest a fundamental relationship between ventilation and indoor temperatures. The higher minimum and average summertime temperatures observed in mechanical ventilation with heat recovery (MVHR) homes (p < 0.05) and lower temperature range (p < 0.001) suggest the need for greater attention to adequate summertime ventilation provision in airtight homes. The results demonstrate a high prevalence of overheating in exemplary housing, indicating the need for greater efforts to ensure the effective implementation of strategies to minimize overheating and improve ventilation in low-energy homes.; Despite growing concerns about overheating, a lack of evidence exists on the scale of the problem, particularly in contemporary UK housing. This paper presents the results of a meta-analysis of indoor temperatures in selected low-energy housing. Temperature data recorded at five-minute intervals in 60 dwellings across 19 demonstration projects (2012-14) were collated and analysed to investigate the prevalence of overheating. Findings evidence high summertime temperatures, with 27% of living rooms exceeding 28°C during August. Based on the Chartered Institution of Building Services Engineers (CIBSE) threshold of 5% annual occupied hours > 25°C, 57% of bedrooms and 75% of living rooms were classified as having overheated. Overall, 30% of living rooms exceeded the adaptive comfort threshold of > 3% occupied hours [Delta]T [greater than or equal to] 1 K. The results suggest a fundamental relationship between ventilation and indoor temperatures. The higher minimum and average summertime temperatures observed in mechanical ventilation with heat recovery (MVHR) homes (p < 0.05) and lower temperature range (p < 0.001) suggest the need for greater attention to adequate summertime ventilation provision in airtight homes. The results demonstrate a high prevalence of overheating in exemplary housing, indicating the need for greater efforts to ensure the effective implementation of strategies to minimize overheating and improve ventilation in low-energy homes.;Despite growing concerns about overheating, a lack of evidence exists on the scale of the problem, particularly in contemporary UK housing. This paper presents the results of a meta-analysis of indoor temperatures in selected low-energy housing. Temperature data recorded at five-minute intervals in 60 dwellings across 19 demonstration projects (2012-14) were collated and analysed to investigate the prevalence of overheating. Findings evidence high summertime temperatures, with 27% of living rooms exceeding 28 degrees C during August. Based on the Chartered Institution of Building Services Engineers (CIBSE) threshold of 5% annual occupied hours > 25 degrees C, 57% of bedrooms and 75% of living rooms were classified as having overheated. Overall, 30% of living rooms exceeded the adaptive comfort threshold of > 3% occupied hours T1K. The results suggest a fundamental relationship between ventilation and indoor temperatures. The higher minimum and average summertime temperatures observed in mechanical ventilation with heat recovery (MVHR) homes (p<0.05) and lower temperature range (p<0.001) suggest the need for greater attention to adequat summertime ventilation provision in airtight homes. The results demonstrate a high prevalence of overheating in exemplary housing, indicating the need for greater efforts to ensure the effective implementation of strategies to minimize overheating and improve ventilation in low-energy homes.;
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | heat stress; thermal performance; building performance; housing; overheating; ventilation; low-energy buildings; vulnerability; comfort; air-quality; passivhaus dwellings; performance; climate-change; overheating risk; future; low-energy houses; construction & building technology; thermal environment; temperature; buildings; meta-analysis |
| Index terms: | vulnerability, strategy, implementation, heat stress, mechanical ventilation, overheating, building performance, indoor temperature, ventilation, bedroom, low-energy house, evidence, passivhaus dwelling, thermal performance, adaptive comfort, housing, building services engineer, comfort, thermal environment, meta-analysis, new-build housing, building technology, recovery, low-energy building |
| Subjects: | quality assurance, health safety and environment, profession, research evaluation and metrics, contractual arrangements, management, environmental health, thermal systems, occupational health and safety management, environmental hazards, operations management, evaluation and assessment methods, economic development, environmental engineering, environmental science, construction type, energy efficiency, human factors, architectural elements, air quality, energy systems, engineering systems |
| Topics: | Design Practice, Project Management, Quality Management, Health and Safety, Research Practice, Construction Technology, Urban Studies, Sustainability, Procurement, Engineering Principles, Business Strategy, Roles and Professions |
| Descriptive scope: | 3 PCA |
N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here