The actual performance of retrofitted residential apartments: Post-occupancy evaluation study in Italy

Elsayed, M; Romagnoni, P; Pelsmakers, S; Castaño-Rosa, R and Klammsteiner, U (2023) The actual performance of retrofitted residential apartments: Post-occupancy evaluation study in Italy. Building Research & Information, 51(4), pp. 411-429. ISSN 0961-3218

Abstract

Housing retrofits are undertaken to reduce energy use and to improve 'occupants' indoor environmental conditions. Despite increased retrofitting of the Italian housing stock, there is a lack of data on their energy use and indoor environmental quality (IEQ). This paper fills this gap by a post-occupancy evaluation (POE) study of seven retrofitted apartments in northern Italy; a non-retrofitted case study was included as a comparison. The study aimed to understand aspects of IEQ and occupant satisfaction after energy-efficiency retrofits. A mixed-method approach encompassed occupant satisfaction surveys, energy bill comparisons, in-situ indoor air temperature, and relative humidity measurements. Results highlighted 'occupants' thermal comfort improvement and heating energy consumption reduction after retrofits. Furthermore, reported preferred indoor temperatures w within a broader range than the recommended Italian regulations and CIBSE guide A standard. However, some participants reported unintended consequences, including mould growth and noise from the mechanical ventilation system. This study shows the potential of POE to understand the actual performance of retrofitted residential buildings. However, the difficulties of conducting a POE in retrofitted existing residential buildings show the need of further research on how to effectively conduct POE in retrofitted residential buildings, including improved digital quality monitoring methods.

Item Type: Article
Uncontrolled Keywords: energy-efficient retrofit; indoor environmental quality; occupant satisfaction; post-occupancy evaluation
Index terms: retrofitting, housing, relative humidity, environmental conditions, mould, Italy, regulation, survey, mechanical ventilation, housing stock, unintended consequence, indoor temperature, energy use, indoor environmental quality, occupant satisfaction, thermal comfort, in-situ, monitoring, energy consumption, air temperature, post-occupancy evaluation, case study, residential building, efficiency
Subjects: performance management, renovation and retrofit, Geography, building construction, environmental engineering, political science, environmental hazards, environmental health, industry analysis, user-centered design, air quality, risk assessment, construction type, data collection methods, control systems, evaluation methods, environmental science, energy systems
Topics: Engineering Principles, Geographical Context, Research Practice, Business Strategy, Governance, Sustainability, Construction Technology, Risk Management, Quality Management, Design Practice, Site Management
Descriptive scope: 3 PCE

N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here