Occupant thermal comfort and indoor environmental conditions in Mies van der Rohe's S.R. Crown hall

Mitkees, L; Heidarinejad, M; Sabatino, M and Stephens, B (2024) Occupant thermal comfort and indoor environmental conditions in Mies van der Rohe's S.R. Crown hall. Building Research & Information, 52(3), pp. 249-272. ISSN 0961-3218

Abstract

There is little empirical data in the published literature on occupant thermal comfort in buildings from the Modern Movement in architecture. We present a field survey of occupant thermal comfort and indoor environmental conditions in Mies van der Rohe’s modern S. R. Crown Hall (1956) on the campus of Illinois Institute of Technology in Chicago, IL. Surveys were deployed to 557 student participants on four separate days, including two days in the cooling season and two days in the heating season, to assess their perceptions of thermal comfort throughout the space. Indoor air temperature, relative humidity and mean radiant temperature were measured concurrently in several locations throughout the space. Occupants reported high levels of dissatisfaction with comfort in the space (percent dissatisfied ranging 37%–54%), with somewhat counterintuitive results for this building type. Overcooling was apparent during warm weather and a combination of both over- and under-heating occurred during cold weather, contrary to what was expected in this building with a high thermal transmittance enclosure. There was also high spatial variability in comfort responses and measured indoor environmental conditions. Findings highlight the need to develop contextual approaches to meeting occupant comfort needs in this building while preserving architectural aesthetics/intent.

Item Type: Article
Uncontrolled Keywords: indoor environment; Mies van der Rohe; modern architecture; modern heritage; modern movement; Occupant thermal comfort
Index terms: movement, survey, environmental conditions, relative humidity, weather, enclosure, aesthetic, indoor environment, air temperature, thermal comfort, comfort, variability, cold weather
Subjects: occupational health and safety management, statistical analysis, environmental engineering, factor and component analysis, architectural elements, environmental science, data collection methods, air quality, health behaviours and lifestyles
Topics: Health and Safety, Research Practice, Sustainability, Design Practice
Descriptive scope: 3 PCE

N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here