The effectiveness of the parametric design 'sudare' blind as external shading for energy efficiency and visibility quality in Jakarta

Hariyadi, A; Fukuda, H and Ma, Q (2017) The effectiveness of the parametric design 'sudare' blind as external shading for energy efficiency and visibility quality in Jakarta. Architectural Engineering and Design Management, 13(5), pp. 384-403. ISSN 1745-2007

Abstract

Recently, Jakarta has implemented a new standard for new building construction to reduce the energy consumption of office buildings. This has to meet the minimum overall thermal transfer value (OTTV) of 35 watt/m2. In tropical countries, the most effective passive design strategy method is the use of shading devices. Dense shading will more effectively reduce energy consumption but will reduce visibility through the opening. Sudare is a traditional Japanese blind made from bamboo.Its original function was to prevent direct solar radiation and introduce natural ventilation. The characteristic Sudare form makes it possible to see through to objects outside the house. The aim of this research is to identify an alternate mode of façade configuration using external horizontal blinds based on the Sudare form to meet the minimum standard of Indonesian National Standard (SNI), with greater efficiency in terms of thermal energy use to minimize energy consumption and maintain visual comfort. Ladybug and Honeybee inside the Grasshopper plugin of Rhinoceros 3D with the Energy plus engine will be used to simulate a standard building as baseline performance, and buildings that use different Sudare dimensions and spacers as shading devices parametrically. Based on this study, the optimum form of Sudare blind, with a diameter of 10.01 mm and 5 mm spacers, has achieved a 5% reduction in OTTV and a 6% reduction in thermal energy use, as compared to the baseline building. It also gives better uniformity of daylight distribution, which improves visual performance and comfort.Recently, Jakarta has implemented a new standard for new building construction to reduce the energy consumption of office buildings. This has to meet the minimum overall thermal transfer value (OTTV) of 35 watt/m 2 . In tropical countries, the most effective passive design strategy method is the use of shading devices. Dense shading will more effectively reduce energy consumption but will reduce visibility through the opening. Sudare is a traditional Japanese blind made from bamboo.Its original function was to prevent direct solar radiation and introduce natural ventilation. The characteristic Sudare form makes it possible to see through to objects outside the house. The aim of this research is to identify an alternate mode of façade configuration using external horizontal blinds based on the Sudare form to meet the minimum standard of Indonesian National Standard (SNI), with greater efficiency in terms of thermal energy use to minimize energy consumption and maintain visual comfort. Ladybug and Honeybee inside the Grasshopper plugin of Rhinoceros 3D with the Energy plus engine will be used to simulate a standard building as baseline performance, and buildings that use different Sudare dimensions and spacers as shading devices parametrically. Based on this study, the optimum form of Sudare blind, with a diameter of 10.01 mm and 5 mm spacers, has achieved a 5% reduction in OTTV and a 6% reduction in thermal energy use, as compared to the baseline building. It also gives better uniformity of daylight distribution, which improves visual performance and comfort.

Item Type: Article
Uncontrolled Keywords: energy conservation; parametric analysis; ottv; sudare; horizontal shading; energy efficiency; construction standards; energy consumption; construction; energy use; buildings; shading; devices; shading devices; thermal energy; spacers; visual perception; reduction; daylight; office buildings; ventilation; visibility; power efficiency; solar radiation; bamboo; blinds
Index terms: shading, dimension, energy use, thermal energy, visual comfort, energy conservation, parametric analysis, energy consumption, visual perception, natural ventilation, configuration, comfort, power efficiency, effectiveness, overall thermal transfer value, strategy, horizontal shading, solar radiation, building construction, passive design, parametric design, office building, ventilation, energy efficiency, efficiency, bamboo, construction standard, spacer, Jakarta
Subjects: design methods, construction type, air quality, data analysis and analytics, energy systems, standards, health monitoring assessment and metrics, sustainability and energy, Geography, building design, architectural elements, management, performance management, traditional and composite building materials, thermal systems, systems engineering, environmental engineering, occupational health and safety management, building construction, cognitive psychology
Topics: Quality Management, Legal Issues, Design Practice, Engineering Principles, Construction Materials, Research Practice, Geographical Context, Health and Safety, Business Strategy, Sustainability, Construction Technology
Descriptive scope: 3 PCA

N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here