Alongi, A; Angelotti, A; Rizzo, A and Zanelli, A (2021) Measuring the thermal resistance of double and triple layer pneumatic cushions for textile architectures. Architectural Engineering and Design Management, 17(3-4), pp. 334-346. ISSN 1745-2007
Abstract
Lightweight architecture, implementing coated fabric and membrane materials, increasingly adopts multiple layer pneumatic cushions in order to guarantee adequate thermal insulation and better indoor comfort, especially in permanent buildings. The cushion thermal transmittance decreases as the number of layers increases. However, the U-value is generally assessed by simple calculations assuming the cushion layers are parallel planes. This way, any effect of the curved geometry of the cushion on the heat transfer is disregarded. In this paper, an experimental approach to evaluate the overall U-value of multiple layer cushions is proposed. Two sample cushions of about 1 m2 made up of PVC-coated polyester are built, one double layer and one triple layer. They are tested in vertical position in a double thermal chamber laboratory apparatus, establishing a constant temperature difference equal to 25°C across them. The cushion surfaces are divided into thermally homogeneous portions where temperature and heat flow density probes are centrally placed. In parallel, the U-values are calculated using literature correlations for free convection in rectangular cavities and assuming radiative heat transfer between parallel grey surfaces. The experimental results show that, passing from two to three layers, the overall thermal resistance of the cushion almost doubles (+ 91%) and the thermal transmittance reduces by about 30%. At the same time, simple calculations of the U-value underestimate the insulation capacity of the cushions, especially for the double layer one. Further investigations are necessary to understand the impact of the cushion shape on free convection in the air cavity.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | energy performance; free convection; heat flow; measurement; multilayered membrane skin; pneumatic cushion; thermal resistance; thermal transmittance |
| Index terms: | cushion, insulation, energy performance, thermal resistance, comfort, investigation, thermal insulation, geometry, guarantee, density, laboratory |
| Subjects: | energy systems, analytical methods, building materials, data collection methods, mathematical modelling, occupational health and safety management, research management, material properties and characteristics, contract structure |
| Topics: | Design Practice, Urban Studies, Health and Safety, Research Practice, Construction Materials, Procurement, Sustainability |
| Descriptive scope: | 3 PCA |
N.B. Descriptive scope is a count of how many of the five facets of empirical research are indicated by the words used in title, abstract and keywords. It is not intended as a judgement on the research; merely a count of the kind of word we would expect to indicate Phenomenon, Concepts, Theoretical framing, Empirical techniques, Analytical techniques. If all five are present, then a code of “5 PCTEA” will indicate this. If you feel the coding for this record is questionable, we welcome discussion around the terms we matched or the way we categorized them. The facet you would expect may not be coded, or a facet may be coded inappropriately. This can also bear on a larger question, of which facets should be treated as defining in construction management research. Please get in touch, and we will look at it. More details here